SIGLENT Expands SDM4000A Series with New 7½-Digit Precision Multimeter
Breaking News:
Kathmandu Nepal
Montag, Nov. 23, 2026
Precision Measurements for Demanding Applications
The SDM4075A provides true 7½-digit measurement resolution with 11 million counts and a specified one-year DC voltage basic accuracy of 16 ppm. This makes the multimeter suitable for precision voltage, current, and resistance measurements in research and development laboratories, electronic component characterization, and calibration and verification applications.
The instrument supports DC and AC voltage measurements, DC and AC current measurements, 2-wire and 4-wire resistance measurements, as well as capacitance, frequency, and temperature measurements. The DC voltage measurement ranges extend from 100 mV to 1,000 V, while the DC current measurement ranges cover 1 µA to 10 A. Resistance measurements are supported across ranges from 10 Ω to 1 GΩ. For accurate low-resistance measurements, the instrument provides a 4-wire measurement configuration.
High Measurement Speed and Integrated Digitizer
In addition to its high resolution, the SDM4075A offers a maximum measurement rate of 50,000 readings per second. The integration time can be adjusted between 0.001 and 100 PLC, allowing users to balance measurement speed and noise rejection according to the application requirements.
An integrated digitizer function enables time-resolved acquisition of DC voltage and current signals at sampling rates of up to 2 MSa/s. The analog bandwidth reaches 15 kHz for voltage measurements and 10 kHz for current measurements. Up to two million readings can be captured in a single acquisition.
This functionality supports applications such as analyzing time-dependent signal behavior, transient settling processes, and variations in current consumption within the specified bandwidth.
Comprehensive Data Logging and Analysis
For long-term measurements, the SDM4075A provides internal storage for up to two million readings, including timestamps. When logging to an external file, up to 360 million readings can be recorded. Logging intervals are adjustable from 1 ms to 3,600 seconds, with a maximum recording duration of 100 hours.
For direct measurement analysis, the instrument includes statistical functions such as minimum, maximum, average, and standard deviation, as well as limit testing. Measurement results can be displayed numerically or visualized using bar graphs, trend charts, and histograms.
The 5-inch TFT touchscreen with a resolution of 800 × 480 pixels enables convenient operation and direct analysis of measurement results on the instrument.
Integration into Automated Test Systems
For use in automated test and measurement environments, the SDM4075A is equipped with LAN, USB Device, and USB Host interfaces. An optional USB-GPIB adapter allows integration into existing GPIB-based systems.
Support for standard SCPI commands enables remote control and integration into automated test sequences. An external trigger input and a VMC output are also available for synchronization with other measurement instruments.
The integrated web server and VNC support allow remote operation of the instrument. The EasyDMM-X PC software provides additional capabilities for instrument control and data acquisition.
Expanding the SDM4000A Series
With the introduction of the SDM4075A, SIGLENT extends its existing SDM4000A series with a model designed for applications requiring increased measurement resolution, accuracy, and time-resolved data acquisition. The instrument combines traditional precision measurement functions with extensive data analysis and system integration capabilities.
SIGLENT TECHNOLOGIES began in 2002 with the development of its first digital oscilloscopes. Since then, the company has rapidly expanded its portfolio to cover a broad range of general-purpose electronic test and measurement instruments, including oscilloscopes, signal and function/arbitrary waveform generators, digital multimeters, laboratory power supplies, electronic DC loads, spectrum analyzers, vector network analyzers (VNAs), and RF signal generators.
With the introduction of the Performance Line Series in 2021, SIGLENT further advanced its technical capabilities to address demanding applications in high-performance measurement environments, including solutions reaching into the microwave frequency range up to 40 GHz.
Today, SIGLENT TECHNOLOGIES is a globally recognized provider of electronic test and measurement equipment, combining innovative features, strong engineering expertise, and reliable performance. Headquartered in Shenzhen, China, with international subsidiaries in the United States, Germany, Japan, and Malaysia, SIGLENT supports customers in more than 80 countries worldwide.
SIGLENT is certified according to ISO 9001:2015 and ISO 14001:2015 standards, reflecting its commitment to consistent product quality and responsible environmental management.
SIGLENT Technologies Germany GmbH
Stätzlinger Str. 70
86165 Augsburg
Telefon: +49 (821) 66601110